Papers · Paper 2 · preprint, under review
Manifold polarity as the geometric cause of cross patient failure in Riemannian EEG seizure detection
Reframes polarity from binary classification (standard/inverted) to a continuous strength measure. Hardware scaling across CH8, CH12, and CH16 configurations reveals that polarity magnitude depends on circuit depth and coherence budget.
Preprint: Research Square, posted 6 October 2026, CC BY 4.0 · DOI 10.21203/rs.3.rs-10787059/v1
Abstract
Manifold polarity, first identified as a binary property in Paper 1, is more accurately described as a continuous projection of the patient’s covariance shift onto the circuit’s fixed measurement axis. The sign determines polarity direction; the magnitude determines signal strength. Two patient populations emerge: strongly polar (chb03, chb21) whose polarity is stable across configurations, and weakly polar (chb01, chb05, chb07, chb14) whose polarity direction is configuration-dependent.
Hardware validation summary
All results from IBM Torino (Heron r1), 1024 shots, no error mitigation.
| Configuration | Channels | Qubits | Raw AUC | Oracle-Cal AUC | N Inverted |
|---|---|---|---|---|---|
| CH8 @ 1.95s | 8 | 17 | 0.524 | 0.637 | 3 |
| CH8 @ 20s | 8 | 17 | 0.404 | 0.605 | 6 |
| CH12 | 12 | 25 | 0.522 | 0.565 | 4 |
| CH16 | 16 | 33 | 0.512 | 0.512 | 0 |
Pre-registered prediction outcomes
Honest reporting of pre-registered predictions against actual hardware results:
Patient subset rationale
7 patients selected from CHB-MIT: chb01, chb03, chb05, chb07, chb11, chb14, chb21. Selection criteria: sufficient seizure events for LOSO validation, consistent recording montage, and coverage of both polarity populations identified in Paper 1 simulation results.
Status
Posted as a preprint on Research Square on 6 October 2026 (v1, CC BY 4.0), DOI 10.21203/rs.3.rs-10787059/v1. Under review at the journal; first submitted 22 August 2026.
What changed since
Sharpened 2026-09. Within a patient, the seizure shift direction is coherent across seizures (bias-corrected coherence 0.84–1.00 in 22 patients; shape-only median 0.84). Most of the shift — median 83 % — is a uniform power gain that the trace-normalised state cannot hold; the robust, reference-free polarity is the sign of that power change. The inverted set reported in Paper 2 depends on the reference axis, exactly as the fixed-basis mechanism predicts. Details in results/prompt037–039.